We
can divide widely
four kinds of
technologies
for battery
regeneration
method as follows
;
|
1)
Chemical Additive
(Dry Salt)
|
Fast desulfation,
but it needs
at least two
or three times
of repeated
charge and discharge
processes in
order to make
a chemical activation
(electromotive
force) of battery.
It seems
cheaper, but
not competitive
at all [
MF
/ VRLA - making
halls into all
cells (Sealed)
¡æ
input additive
into all cells
(desulfation)
¡æ charge and
discharge 2~3
times (20~30
hours) ¡æ
MF
/ VRLA seal
off halls of
cells
¡æ surface
sanding, painting,
drying (Sealed)
]
This method
does not have
any merits.
But, it
has any demerits
such as spending
much cost of
electricity,
time, chemical
additive and
labor cost.
Lower
Restoration
results. Easy
to damage cells
by fast melting
of sulfation.
Easy to
make an electric
short by some
settled dregs
caused by rapid
desulfation
result. COMMENT
: Poorest Competition
|
2)
Low Frequency
Pulse Type
|
Nearly all
regenerators
for Forklift
and Telecom
Station &
Golf Cart batteries,
Diode Control
for Big Current,
Current control,
SCR, Time Division
Control,
Fixed Strong
Pulse 60. 120. 180Hz
(Strong Low-Frequency
Pulse). Comparing
with OPTIMORE ;
Very Heavy weight
(200~400 kgs),
3 Phases
380~440VAC,
10~20KW Power
consumption,
Complicated
operation and
maintenance,
Expensive, Damage
to cells by
low-frequency
pulse,
Can give big
damages to small
size batteries(below
300Ah). COMMENT
: Poor
Competition
|
3)
SMPS Noise Pulse
Type (Direct
Current with
Higher charging
voltage)
|
Most SMPS
Type regenerators.
But it
is not a real
High-Frequency
Pulse Type.
SMPS makes desired
voltages by
high-frequency
switching after
changing
Alternating
Current (AC)
into Direct
Current (DC).
In this, if
generated electricity
was supplied
to a battery,
due to resisting
load in a
battery itself,
it would have
a high possibility
that a component
in SMPS (FET)
would be damaged.
Thus, since
output shock
from SMPS should
be relieved,
by using a condenser
and a choke
coil, resisting
load inside
of a battery
would be minimized.
Therefore, actually
supplied thing
from SMPS to
a battery can
be Direct Current
(DC) rather
than High-Frequency
Pulse. SMPS
can actually
make High-Frequency
Pulse, however
ironically,
SMPS of other
competitors
prevent to output
High-Frequency
Pulse due to
the damage of
their regenerators.
Because of this
technical limitation,
there was no
company can
solve the problem
providing real
High-Frequency
Pulse to a battery
from regenerator
directly. That
is a reason
that regenerators
using High-Frequency
Pulse could
not be boosted
and commercialized
so far. All
the other competitors
insist that
their technology
is based on
High-Frequency
Pulse, but they
can show some
signals through
screen of Oscilloscope
by connecting
two Probes coming
from the transformer
of SMPS. However,
that can be
wrong measurement
and pulse which
doesn't enter
into a battery
gives any help
to the regeneration.
Definitely,
real High-Frequency
Pulse should
be confirmed
by connecting
probes to battery
terminals. Since
High-Frequency
Pulse is too
much weak, it
can't provide
any help for
regenerating.
Due to those
limitations,
since
direct connection
to the battery
terminals with
Oscilloscope
can be showing
as direct current
(DC) only, so
other companies
never show it
to customers.
COMMENT
: Most
of SMPS type
regenerator
have no high-frequency
pulse. They
have only SMPS
pulse noise
that it is almost
no relation
with battery
restoration.
It is
faked technology.
We
can define their
technology as
Direct Current
Type Regenerators
with Higher
charging voltage
charging. COMMENT
: Poor Competition
|
4) High Frequency
Pulse Type (Current
inclusive Real
High Frequency
Pulse - OPTIMORE)
|
We believe
that OPTIMORE regenerator
are the one
and only this
type. It
can prove by
an Oscilloscope
that The Pulse
image of OPTIMORE
product is like
below. This
picture is photographed
directly in
our company
by connecting
oscilloscope
to the +, -
terminals of
the battery
after connecting
between OPTIMORE
regenerator
and the battery.
Anyone
who knows little
bit about Pulse,
you could know
that this Pulse
Wave is a unique
high frequency
regeneration
pulse of our
own.
|
|
OPTIMORE regenerators
are the only
regenerator
which can make
the superior
regeneration
by supplying
real High-Frequency
Pulse included
current at the
same time. OPTIMORE
regeneration
is a function
of improving
the performance
and the electromotive
force of used
batteries. By selecting
battery type,
voltage, and
capacity of
a battery respectively,
charging and
regeneration
would be occurred
at the same
time and it
is a function
of regenerating
electromotive
force by increasing
equalization
and specific
gravity of Cells.
Basically, it
is set to 15
hours and the
setting time
can be changed
according to
the voltage
and the capacity.
|
We are
able to change
the whole paradigm
on the battery
use, maintenance
and regeneration
all over the
world. There
will be a huge
market for battery
regenerators.
In near future,
we can see battery
regeneration
shops everywhere
in the world.
Under thesituation,
we would like
to expand the
OPTIMORE battery
regeneration
centers all
over the world.
There is no
doubt that our
innovative products
make a great
franchise chain
for battery
regeneration/restoration.
Thus, we have
the best A to
Z franchise
solutions than
other competitors.
Therefore, we
will be the
one who can
make this franchise
business only
in the world.
Would you like
to makethe first
franchise enterprise
of OPTIMORE battery
regeneration
center together.
And many customers
are ready for
the setting
the regeneration
centers in franchise
in their countries.
I hope your
esteemed company
will be our
close partner
in near future
with your valuable
business experience.
|
|
|
|
|
¢º
|
DC Current
Tester measures
a value of RMS(Root
Mean Square)
to check the
DC component.
(Measured by
the Area)
|
¢º
|
In case
of Low-frequency
Pulse Type :
if the regenerator
sets up 10A
for a battery
charge current,
it needs 15A(average)
and 30
~ 50A (peak)
real current.
So,
it can be damaged
to the battery
and input power
consumption
will be very
high.
(It is
hard to use
for even one
12V battery
at home)
|
|
-
Input Power
Consumption
: 220V X 15A
= 3,300W (Real
Power Consumption) -
Output Power
Consumption
:15V X 10A =
150W
(Working Power
Consumption) *
3,300W
- 150W = 3,150W
(Loss Power
Consumption
by equipment
itself and regeneration)
|
¢º
|
OPTIMORE(High-frequency
Pulse Type)
is similar as
DC current,
therefore, the
power consumption
is almost similar
between Input
and Output
power consumption.
|
|
¡Ü
General Multi
Power Plug is
10A = 12V x
max. 6 batteries.
-
Input Power
Consumption
: 220V
X 1.2A = 260W
(Real Power
Consumption) -
Output Power
Consumption
: 15V X 10A
= 150W
(Working
Power Consumption) *
260W -
150W = 110W
(Loss Power
Consumption
by equipment
itself and regeneration)
|
|
We
have several customers in
50 countries and they are
very satisfied with the
restoration performance
and our after sales service.
|
|
|
|
|